Continuous production crimp contact 4 hours need to stop and cool the mold to below 40℃ to prevent thermal expansion from affecting crimp contact pin precision. contact socket crimp The mold is disassembled and cleaned after every 5000 operations, and the wear of the positioning pin is checked. If it exceeds 0.01mm, replace it with a new one. Operators wear anti-cut gloves and goggles, and the response speed of the crimp contact female equipment emergency stop button is tested once a week. In terms of environmental protection, waste lubricants and plastic residues are classified as hazardous waste and stored and handed over to qualified units for treatment.