News

Mechanical Tensile Test Of Cold Press Needle Crimping Device

Publish Time: Author: Site Editor Visit: 2

After completing the contact crimper crimping operation, a mechanical tensile test is necessary. This is to determine whether the crimping meets the specifications from a mechanical strength perspective.

d sub contact crimper After crimping, the terminal and wire connection should be allowed to stand for a period of time to eliminate internal stress. Then, using a dedicated tensile testing machine, apply a vertical tensile force until the terminal detaches from the wire. Record the maximum pull-out force value and compare it with the minimum pull-out force standard corresponding to the wire cross-sectional area and terminal specifications.

If the test results are below the standard requirements, then the crimping of contact crimping tool cannot be considered qualified. Low pull-out force usually indicates weak internal contact during crimping, which may cause the wire and terminal connection to loosen or detach. This is especially important for production batches; a number of samples should be randomly selected for tensile testing.

Mechanical Tensile Test Of Cold Press Needle Crimping Device

Recent News
Recommended Products

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.